HVAC

19

the Fresh Air Mode and Power A/C is selected. On

turning the knob back to Chest/ Chest-Leg/Leg Mode

from Leg Defrost/ Defrost Mode, the last selected

settings are restored (provided that there has been

no user intervention in between).

The Mode knob Rotary ring Total Rotation Span is

270° with 5 detents, each of 67.5° (between detents),

including both the end positions. The Position of the

mode actuator is based on the Knob position of the

Control Panel during the Ignition ON / OFF.

PINOUT

Pin

NO.

Rotation from

Face to Def. Posi-

tion

Rotation from

Def. to Face Posi-

tion

1

Ground (Pot)

Ground (Pot)

2

Feedback Signal

From pot. to Con-

trol Panel

Feedback Signal

From pot. to Con-

trol Panel

3

+Ve (Pot.)

+Ve (Pot.)

4

NC

NC

5

Motor Grd.

Motor +Ve

6

Motor +Ve

Motor Grd.

14. INSPECTION OF MODE AND TEMPERATURE ACTUATOR

The actuator door flap is positioned on the mode/temperature detent select by the user by means of the re-

spective rotary knob. The control panel provides voltage corresponding to the user selected knob position.

The servomotor in the actuator cause the door flaps to move to the desired location and provide a feedback

signal to the control panel.

1. To calibrate the actuator follow the below steps

2. Turn the IGN OFF and disconnect the battery.

3.Wait for approximately one minute and then reconnect the battery.

Once the battery is connected again wait for one minute and turn the IGN ON. Actuators are now calibrated.

Wait for one more minute after IGN is turned ON until the actuators are calibrated

Feedback Signal Values for Mode Actuator

Sr.

No.

Detent

Position

Mode se-

lected

Knob angle in

degrees (CW

starting from ini-

tial chest mode)

voltage

Min (V)

Nominal (V)

Max (V)

1

1

Chest

1.0

1.05

1.1

2

2

Chest-Leg

67.5º

1.6

1.65

1.7

3

3

Leg

135º

2.23

2.28

2.33

4

4

Leg-Defrost

202.5º

2.87

2.92

2.97

5

5

Defrost

270º

3.48

3.53

3.58