ELECTRICAL
254
8.3 Operating Voltage Range
DESCRIPTION
REQUIREMENT
VOLTAGE
User Customization
settings
Normal operating voltage range
9V-16V
8.4 Operating Temperature Range
DESCRIPTION
REQUIREMENT
VOLTAGE
User
Customizati
on settings
Operating temperature range
-30
c to +85
c
Storage temperature range:
-40
c to +105
c
8.5 Inputs & Outputs
Inputs
Outputs
IgnKeyStateIGN---->
---->BCMPresence
HuApproachLampSignalVal1---->
---->BCMVariant
HuApproachLampSignalVal2---->
---->BCmUCsStatus
HuApproachLampSignalVal3---->
---->BCmApproachLampState
HuApproachLampActiveSignalVal---->
---->BCmApproachLampSignalVal1
HuDriveAwayLockingActiveSignalVal---->
---->BCmApproachLampSignalVal2
HuAutoRelockActiveSignalVal---->
---->BCmApproachLampSignalVal3
BCmFactorySettingReq---->
---->BCmApproachLampActiveSignalVal
HuQueryInfo---->
---->BCmDriveAwayLockingState
---->BCmDriveAwayLockingActiveSignalVal
---->BCmAutoRelockState
---->BCmAutoRelockActiveSignalVal
User Cutomization
Setting
(With respect to BCM)
required
optional
required
optional