Background Image
Table of Contents Table of Contents
Previous Page  554 / 1232 Next Page
Information
Show Menu
Previous Page 554 / 1232 Next Page
Page Background

Automated Manual Transmission

26

PARAMETER.

What tools are needed?

Diagnosis equipment

Verifying and Checking Procedures C510:

Oil Level Check:

1. Wait for the electric pump to turn off (The

electric pump turns on when the driver's

side door is opened and goes off automat-

ically after a maximum of 30 seconds).

2.

Bring the ignition key to Ignition.

3.

Perform various gear changes with the

engine off (at least 10) until the electric

pump comes on.

4.

Immediately after the electric pump

turns off launch the calibration “accu-

mulator depressurisation” and then check

the oil level of the hydraulic unit.

5.

If the oil level is lower than the Max refer-

ence perform the refilling procedure; if

greater restore to the Max level.

NOTE:

It is good practice to note down the amount

of oil needed for refilling.

Oil Leak Check:

1.

After having checked the oil level (see

procedure 2), note down the amount of

oil needed for refilling.

2.

Carry out a visual inspection of the pipes,

electric pump, reservoir, hydraulic unit,

actuators (engagement/selection, CSC

clutch) whilst carrying out 50 gear changes

from 1st to 5th/Reverse and from

5th/Reverse to 1st (with a frequency of 1

gear change every 3-4 secs).

3.

If leaks are detected replace/repair the

parts involved, refill oil and restart from

point 1.

4.

If no leaks are found:

If the amount of oil before refilling is > 200

cc -> replace hydraulic unit,

If the amount of oil before refilling is < 200

cc -> repeat point 2 checking thoroughly

for any leaks from the CSC clutch,

If it's all ok proceed to the next step in the

diagnosis table.

Oil Pressure Check:

1.

Bring the ignition key to IGNITION ON.

2.

Connect the diagnostic equipment and

read the pressure on it.

3.

With the electric pump off the pressure

should be between 42 and 52 bar at am-

bient temperature.

Electrical Pump Supply Check:

1.

Bring the ignition key to Ignition.

2.

Connect the diagnostic tool equipment.

3.

Check with diagnostic tool that the battery

voltage is greater than 11 V; if the voltage

is lower check the battery.

4.

Display with diagnostic tool the output

status of the pump relay (ON/OFF).

5.

Perform gear changes until the electrical

pump activates.

6.

Suspend the gear change requests and

check how long the electric pump stays on

(feeling the electric pump and looking at

the Diagnostic tool at the same time when

the output status of the relay pump

switches from ON to OFF).

7.

If the parameter's status "pump relay out-

put" is ON, but the electrical pump does

not seem to be on check the electrical

power supply chain for the electric pump

(relay, fuse).