Background Image
Table of Contents Table of Contents
Previous Page  447 / 1265 Next Page
Information
Show Menu
Previous Page 447 / 1265 Next Page
Page Background

1.5L REVOTORQ ENGINE

192

ECU Handling and Care

Earth (Ground) Connection:

1. Ensure all the ground connections are fixed

correctly.

2. DO NOT leave any grounded wire loose or

open.

3. ECU ground pins should be grounded within

300mm from the ECU.

Power Supply:

At IGNITION ON, ECU starts functioning and

initializes, the power for the main drivers for the

ECU are taken from the MAIN RELAY power

supply. The MAIN RELAY output stage gives 12

volts when ECU grounds the MAIN RELAY at

IGNITION ON. After IGNITION OFF the ECU

holds the MAIN RELAY GROUND for some

duration known as the POWER LATCH period so

that the vital functionalities are powered ON for

that duration.

PRECAUTION

Do not disconnect the connector of the

ECU for at least 1 minute after IGNITION

OFF. Never disconnect the connector of

the ECU during IGNITION ON.

Ensure that ignition switch is in OFF

position while plugging - in the connector to

the ECU.

Input

Ensure that the Input signal line is as far as

possible away from noise sources such as

High Tension Cable, Horn relay, Motor etc.

Ensure that sealed wire are used for input line

of lambda oxygen Sensor, Crank Angle

Sensor and the wiring is as far as possible

from the noise sources similar to the ones

above. Sensor ground connections should not

be shorted to 12 volts supply.

Output

Take care to avoid dead-short (solenoid short-

circuit etc.) and similar circuit misconnection

while checking (to avoid any damage). Use a

solenoid which does not use a fly - back diode

(reverse polarity may damage the Output

Power Transistor).

Mounting / Installation Guidelines :

While mounting to the fixation the ECU must

be fixed without deformations. As an ideal

solution, a connection with minimum 3 screws,

screwed on a plan surface, is to be

considered.

Bouncing of the fixed ECU between ECU and

fixation underground is not permissible.

Stagnant humidity and water standing directly

on the sealing area (“bath tub”) between cover

and bottom part or respectively the connector

is not permissible. That means the defined

mounting angles of the offer drawing must be

considered.

Formation of electro-chemical corrosion

created by the use and connection of different

metals within the installation of the control

device is to be avoided.

Following combination of materials are not

acceptable: Steel – Brass - PBT = stress

corrosion cracking (appearance of base at

NaCl load).

The first fixation point of the wiring harness

must be in a distance - 150 mm from the cable

outlet and on the same vibration level as the

ECU.

Relative motion between the wiring harness

and the ECU has to be minimized.

It has to be assured that no water can infiltrate

through the wiring harness into the connector

or the ECU respectively. This can be achieved

by using a Siphon or a breathing hole.

If the Electronic Control Module is coated, it

must be ensured, that the Pressure

Compensation Element (PCE), the connector

and the label are free of coating.

The mounting position of the ECU has to be in

a distance which is large enough from a heat

source to avoid any influence of heat transfer

to the ECU.

The mounting place of the ECU should be

chosen to gain low humidity and corrosion

loads. Permanent water spraying based on

splash water must be avoided by appropriate

protections.

The impact of chemicals (e.g. oils, diesel, and

gasoline, detergents for cleaning, brake fluid,

battery acid, and so on) should be low.