Background Image
Table of Contents Table of Contents
Previous Page  559 / 561 Next Page
Information
Show Menu
Previous Page 559 / 561 Next Page
Page Background

TIAGO/TIGOR AMT Gasoline

DTC Troubleshooting Guide

Version: 4.0

Date: 18-04-2017

Author: Sathi/Anupama

Page: 425 of 427

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

104 P1711-

07

Battery Supply –under low

threshold

-Battery discharged

- alternator not charging

-Wiring Harness

Connections

- TCU

- battery

- alternator

105 P0604-

08

TCU ROM– Checksum Error

-TCU hardware damage

-TCU damage

106 P0604-

07

TCU RAM– Integrity Error

-TCU hardware damage

-TCU damage

107 P062F-

07

TCU EEPROM– Tuning Data

Alteration Error

-TCU hardware damage

-TCU damage

108 P062F-

08

TCU EEPROM– Grid Data

Alteration Error

-TCU hardware damage

-TCU damage

109 P1740-

07

TCU EEPROM– System Data

Alteration Error

-TCU hardware damage

-TCU damage

110 P060A-

07

Safety Microprocessor–

Integrity failure

-Hardware damage

-SMP(safety microprocessor) output

problem

-TCU damage

111 P060A-

08

Safety Microprocessor– Output

failure

-Hardware damage

-SMP(safety microprocessor) output

problem

-TCU damage

112

P0701-

02

Electro valves Driver 1– SPI

Device fault

-TCU hardware damage

-TCU damage

113 P0701-

01

Electro valves Driver 1–

Thermal warning

-TCU hardware damage

-TCU damage

114 P0701-

03

Electro valves Driver 1– Device

closed

-TCU hardware damage

-TCU damage

115 P0701-

04

Electro valves Driver 1– Device

open

-TCU hardware damage

-TCU damage

116 P184D-

02

Electro valves Driver 2– SPI

Device fault

-TCU hardware damage

-TCU damage

117 P184D-

01

Electro valves Driver 2–

Thermal warning

-TCU hardware damage

-TCU damage

118 P0881-

02

TCU 12V Internal Supply –

Device Open

-TCU hardware damage

-TCU damage

119 P0881-

03

TCU 12V Internal Supply –

Device closed

-TCU hardware damage

-TCU damage

120 P0880-

04

SMP 5V power Supply – under

low threshold

-TCU hardware damage

-TCU damage

121 P0880-

06

SMP 5V power Supply – under

medium threshold

-TCU hardware damage

-TCU damage

122 P0880-

02

SMP 5V power Supply – under

low threshold

-TCU hardware damage

-TCU damage

123 P0880-

03

TCU 5V power Supply – Device

Closed

-TCU hardware damage

-TCU damage

124 P1401-

07

Level 2 Intervention-Safety

input failure

-Wiring harness problem

-Input system problem

-Wrong execution

conditions

-TCU damage

125 P1401-

08

Level 2 Intervention-system

problem

-Wiring harness problem

-System problem

-Wrong execution

conditions