HVAC

33

Step

Inspection

Action

negative pressure on low-pressure

side?)

8

Verify whether malfunction is in

expansion valve or receiver/drier.

Turn A/C switch off and air condi-

tioner stop for 10 minutes start

engine turn both A/C switch and

fan switch on. Does malfunction

occur after compressor turn on?

Yes

Go to next step

No

Replace condenser and vacuum refrigerant line

more than 30 minutes by vacuum pump, and re-

frigerant to specified level.

(Since water has

intermixed in receiver/drier and it is saturated,

replacement is necessary.)

9

Verify that expansion vale heat-

sensing tube within cooling unit is

positioned securely and correctly is

expansion valve heat-sensing tube

within cooling unit securely in-

stalled in proper position?

Yes

Replace expansion valve.

(Since valve closes too

much replacement is necessary.)

No

Install heat-sensing tube securely in proper posi-

tion.

10

Inspect refrigerant lines inspect

refrigerant lines

Is piping free of damage and

cracks?

Are piping connections free of

oil grime? (visual inspection)

Are piping installation points on

a/c compressor free of gas

leakage?

Are piping installation on cooling

unit free of gas leakage?

Perform gas leak inspection us-

ing gas leak tester.

Are above items okay?

Yes

Go to next step.

No

If piping or an A/C component is damaged or

cracked, replace it.

11

Inspect evaporator piping connec-

tions in cooling unit for gas leakage

are piping connections for evapora-

tor in cooling unit free of gas

leakage?

Yes

If the vane makes a noise, add 10ml of compres-

sor oil to the A/C compressor. Verify that the

noise is no longer heard. Adjust refrigerant to

specified amounts.

No

If piping is damaged or cracked, replace it.

If there is no damage, go to next step.

12

Inspect evaporator piping connec-

tions in cooling unit for looseness

Yes

Tighten connections to specified torque.

If the vane makes a noise, add 10 ml of compres-

sor oil to the A/C compressor.

Verify that the noise is no longer heard. Adjust

refrigerant to specified amounts.

No

If the vane makes a noise, add 10 ml of compres-

sor oil to the A/C compressor.

Verify that the noise is no longer heard. Replace

O-ring on piping, adjust refrigerant to specified

amounts.

13

Inspect piping connections for

looseness are piping connections

loose?

Yes

Tighten connections to specified torque. If the

vane makes a noise, add 10ml of compressor oil

to the A/C compressor. Verify that the noise is no

longer heard.

Adjust refrigerant to specified amounts.

No

If the vane makes a noise, add 10ml of compres-