ELECTRICAL
258
3. Flow Chart 1 (
Procedure to read Vehicle specific information’s from existing / faulty Instrument
Cluster
):
Connect “On Board Diagnostics”
Cable to Diagnostics Connector
Turn Ignition Key On
Start
Start communication with Instrument Cluster
Select Instrument Cluster option in main menu
Read Distance Traveled information -
“Main Odometer Value” and record
Refer Instrument Cluster Diagnostics user manual
Stop communication with Instrument Cluster
Turn Ignition Key Off
Disconnect “On Board Diagnostics” Cable
from Diagnostics connector
End
The following activities will be completed internally,
once “Start communication” command is given.
Start Instrument Cluster Diagnostics Session
Request Security Access Key
Enter Security Access Key
Read Cluster Option Content -
“Domestic” or “Export” and record.
Refer Instrument Cluster Diagnostics user manual
(
Cluster Option Content is required only if Cluster is High
End Variant - 2870 5430 99 02, else go to next step
)