142

ENGINE 273 MPFI

Fit the strainer assembly to water and oil pump

assembly.

Apply

SEALANT LOCTITE 5910

black colour on

oil sump mating surface on block to ensure leak

proof joint.

NOTE

For best results, clean and dry all surfaces with a

residue free solvent.

Apply continous and even bead of silicone to one

surface surrounding all bolt holes.

Remove excess with knife at once. Assemble

parts immediately.

Do not squeeze out silicone by overtightening

bolts.

Retorque will not be necessary.

Cures to touch in an hour and fully cures in 24

hours measured at 21ºC and 50% relative

humidity.

CAUTION

Risk:

Methyl Ethyl Ketoxime, which may cause eye

irritation and may cause sensation if in contact with

skin, if released during curing.

Safety:

Avoid contact with skin and eyes. Keep

out of reach of children.

First Aid:

In case of contact with eyes, rinse off

immediately with plenty of water and contact a doctor

or Poisonous Information Centre. If swallowed, do

not induce vomiting, contact a doctor or Poisonous

Information Centre immediately and show the

container or the label. After contact with skin, wash

immediately with plenty of soap and water. If effect

persists, seek medical attention.

Fit the oil sump on engine block mating surface.

Tighten the hexagonal mounting bolts to the

specified torque.