FUEL SYSTEM

22

FITMENT OF CNG RECEPTACLE VALVE (On

vehicle):

For fitment procedure follow the Reverse

procedure of ‘Removal’

Ensure fitment of receptacle cap on receptacle.

Installation of “O” Ring:

Open

the Filler Valve CAP manually. 

Extract / remove the “O” Ring from

the neck of 

the filler valve. 

Using Nose pliers extract the circlip. 

Replace Wire Mesh filter with the New wire 

Mesh filter. 

Place the circlip using nose pliers. 

Apply siliconic oil (Loxeal 1000) on new O‐ring 

before replacing. 

NOTE:

Do not apply tar, paint, grease or any other

material inside the receptacle as this could

impair performance of the Receptacle valve.

During service always insure the manual shut–

off valve of cylinder valve is closed & the vehicle

is parked in well ventilated area.