Background Image
Table of Contents Table of Contents
Previous Page  910 / 1904 Next Page
Information
Show Menu
Previous Page 910 / 1904 Next Page
Page Background

HVAC

857

HVAC

(d)

Manifold gauge will show following readings if moisture enters in the cycle:

Troubleshooting chart for above condition:

Symptom

Problem

Cause / Reason

Remedy

AC system periodically Air conditioner operates Freezing of expansion Check and clean or replace

cools and then fails to normally at the beginning valve due to presence receiver dryer & expansion

cool.

but over time vacuum is of moisture.

valve which may possibly

created on low pressure

clog. Be sure to evacuate

side.

the air after finishing the

remedy so as to remove

moisture.

(e) Manifold gauge will

show following readings under compression failure of compressor:

Troubleshooting chart for above condition:

Symptom

Problem

Cause / Reason

Remedy

No cooling

Pressure on low pressure Compressor defective Check and repair or replace

side is high and pressure

compressor

on high pressure side is

low