ENGINE
DTC
DESCRIPTION
CAUSE
DIAGNOSTIC
LAMP (
MIL
)
DIAGNOSTIC
LAMP (
CEL
)
Gil When
Driven In CNG
PROBABLE TROUBLE AREA
P0130
Upstream Oxygen
Sensor Circuit
Open/short to
ground.
Signal Error/short
to ground
ON
OFF
ON
1) Loose/ Damaged Connections or Intermittent fault.
2) Sensor supply line Short circuit to Battery/ Ground.
3) Sensor Signal line Short circuit to Battery/ Ground.
4) Check the continuity from sensor connector pins to the ECU pins.( ECU pin 155- Sensor Pin 1; ECU pin 246- Sensor Pin 2; ECU Pin
204- Sensor Pin 3; ECU pin 230- Sensor pin 4.) .
5) Check for back out of pins at both Sensor connector and ECU connector.
6) Check for damage of pins at both sensor connector and ECU connector.
7) Faulty Upstream HO2S1 Sensor.
8) Faulty ECU
P0132
Upstream Oxygen
Sensor Circuit
short to battery
Short Circuit to
Battery
ON
OFF
ON
P0133
Upstream Oxygen
sensor slow
response
Slow response of
the sensor voltage
ON
OFF
ON
P0134
Upstream Oxygen
Sensor Circuit
Signal not
plausible
Signal Out of range
ON
OFF
ON
1) Loose/ Damaged Connections or Intermittent fault.
2) Sensor supply line Short circuit to Battery/ Ground.
3) Sensor Signal line Short circuit to Battery/ Ground.
4) Check the continuity from sensor connector pins to the ECU pins.( ECU pin 155- Sensor Pin 1; ECU pin 246- Sensor Pin 2; ECU Pin
204- Sensor Pin 3; ECU pin 230- Sensor pin 4.)
5) Check for back out of pins at both Sensor connector and ECU connector.
6) Check for damage of pins at both sensor connector and ECU connector.
7) Faulty Upstream HO2S1 Sensor.
8) Faulty ECU
P0135
Upstream Oxygen
Sensor Heater
Control Circuit
Open/Short circuit
Open /Short circuit
ON
OFF
ON