HV ELECTRICAL SYSTEM 72  Initially apply pre torque of 20 nm as per sequence and then apply full torque= 4.5-5.0 kg-m  TIGHTENING TORQUE= 4.5-5.0 Kg-m Image is for reference purpose only. STEP 4  Sheet metal bracket bolted to BIW first then C mount link assembly is bolted to it. Use 2mm thick bright washer on bolt head side while bolting C mount link assy to sheet metal bracket.  HEX FL SCR M10X25, TS17070-8.8SS8451S2-Y, 2 Nos. Apply specified torque.  H/FL BOLT M10X75 TS17130 10.9SS8451S2-YH; NYLOC NUT M10 IS700210-SS8451S2-YH , 1 Nos. Apply specified torque.  C mount link is bolted to C mount.  H/FL BOLT M10X80 TS17130 10.9SS8451S2-YH, NYLOC NUT M10 IS700210-SS8451S2-YH,1 Nos each, Apply specified torque.  Torqueing sequence for C Mount to Bracket & Subframe.  TIGHTENING TORQUE 4.5-5.0 Kg-m 5.0-5.5 Kg-m Image is for reference purpose only.