H. BLOWER CONTROLLER MODULE In case of FATC, a LPM is use to enable the ECU to control the blower speed in smaller increments. It is mounted on evaporator housing. PINOUT Connector 1 Connector 2 REMOVAL 1. Access the linear power module location from co-drivers side. Remove the electrical connection from the module. 2. Remove the mounting screws and take out the module along with the cover. 3. Remove the mounting screw of the module and take out from the cover. REFITMENT For refitment, follow reverse procedure of removal. PIN NO DESCRIPTION 1 2 3 BLOWER MODULE CONTROL SIGNAL 4 5 GND 6 - BAT PIN NO DESCRIPTION 3 + BLOWER 4 - BLOWER FATC 33