9. BLOWER UNIT REMOVAL AND ASSEMBLY LOCATION It is located on the right top side of the HVAC unit. REMOVAL 1. Remove steering column cover. 2. Access the blower from driver side. Remove the electrical connection from the module. 3. Loosen and remove mounting screw of blower motor. 4. Rotate blower assembly in anticlockwise direction & take out the same. REFITMENT For fitment, follow reverse procedure of removal. FATC 27