This actuator operates the flap inside Fresh air inlet; this flap opens/closes the vent for outside air into HVAC unit. F. BLOWER CONTROL MODULE It is mounted on evaporator housing. PINOUT REMOVAL AND ASSEMBLY REMOVAL 1. Remove steering column cover. 2. Access the blower control module from driver side. Remove the electrical connection from the module. 3. Remove the mounting screws and take out the module along with the cover. 4. Remove the mounting screw of the module and take out from the cove. REFITMENT For fitment, follow reverse procedure of removal. PIN NO DESCRIPTION 1 CONTROL 2 DIAGNOSTICS 3 - MOTOR 4 + BAT 5 GND FATC 26