TIAGO/TIGOR ICNG TWIN CYLINDER - SERVICE MANUAL

1.2L REVOTRON TWIN CYLINDER CNG ENGINE 63 4. Install the receptacle on the vehicle and tighten the receptacle to 3.5 to 4 Kgm torque and check for leakages if any. IX. CNG filter Replacement The Filter maintenance is suggested every 30000 km if used on CNG/LPG systems. Removal steps 1. Filter to be dismantled from mounting bracket by removing 2 screws without removing hoses / Oetiker clamps at inlet / outlet ports, rail end, HPR end etc. 2. Filter should be tilted to 90 deg to remove filter cup/bowl with the help of allen key CAUTION Ensure minimum size of across flat should be 10.00mm.

RkJQdWJsaXNoZXIy MTIwNTUz