HVAC 19 G. AIR INLET ACTUATOR The actuator used to operate the air intake door is a bi-directional with no feedback actuator. It controls the air intake door through the air intake control voltage. PINOUT PIN NO DESCRIPTION 1 Not Used 2 Not Used 3 Not Used 4 Not Used 5 + VE 6 Ground INSPECTION When 12.0V supply is given to pin 5 and pin 6, the movement of the actuator should follow the following table. Motor Movement Input Pin 5 Pin 6 Clockwise rotation + VE - VE Counter Clockwise rotation - VE + VE