1.2L REVOTRON ENGINE 185 CONNECTOR DETAILS PINOUT DETAILS Pin No Description 1 Supply 2 EGR Command Vacuum Measurement Values Equipment: Vacuum Gauge Sr No Engine Speed Vacuum Pressure (mm of HG) - Minimum EGR EVRV RPM Inlet Outlet 1 800 (Idle) 650 270 2 2000 640 260 3 3000 640 260 4 4000 640 0 5 4700 (Fly Up) 640 0 VII. START STOP SWITCH Start Stop Switch also known as Push to Start Button. This is main component to trigger engine cranking and controls the completer vehicle power mode (OFF, ACC, IGN, & CRANK) for entire vehicle architecture. It is provided with multicolor LED to indicate different vehicle conditions to customer, OFF (No color) ACC ON (Amber) IGN ON (Green) CRANK ON (Green) Engine Run (Green) SWITCH LOCATION