ELECTRICAL 247 SR. NO. PARAMETERS CHARACTERISTICS 6 Outside Ambient Temperature Range: -199 to +199 (2 1/2 digits, Leading zero’s shall be suppressed) Resolution: 1 °C / °F G. FUEL COMPUTER: Fuel Computer information is available to user, as indicated in table below, which can be selected by user by using “DIC” & “Trip” switches 1. Type 1: Distance unit as “km” SR. FUNCTION TEXT ON DISPLAY UNIT Option 1 Option 2 Default (Factory set) 1 Instantaneous Fuel Consumption Km/l L/100km Domestic – km/l Export – L/100km 2 Average Fuel Consumption “A” Km/l L/100km Domestic – km/l Export – L/100km 3 Average Fuel Consumption “B” Km/l L/100km Domestic – km/l Export – L/100km 4 Range (Distance to Empty) km - “km” for Domestic & Export 2. Type 2: Distance unit as “miles” SR. FUNCTION TEXT ON DISPLAY UNIT Option 1 Option 2 Default (Factory set) 1 Instantaneous Fuel Consumption MPG - MPG 2 Average Fuel Consumption “A” MPG - MPG 3 Average Fuel Consumption “B” MPG - MPG 4 Range (Distance to Empty) mi - mi 3. Instantaneous Fuel Consumption: Updates display “Instantaneous Fuel consumption” at regular time intervals.Instantaneous Fuel Consumption display is available in “km/l” or “L/100km” which can be selected by user by using “DIC & Trip” switches Instrument Cluster displays “Instantaneous Fuel Consumption data” only when the Vehicle speed is ≥ 10 km/h. Instrument Cluster displays "0.0", till the above condition is met. INST FUEL AVG FUEL A AVG FUEL B RANGE INST FUEL AVG FUEL A AVG FUEL B RANGE OUTSIDE TEMP 38°C OUTSIDE TEMP 100°F