HVAC 887 HVAC PRESSURE SWITCH Removal 1. Recover the refrigerant using Refrigerant Recovery Uni t (RRU) (Refer Refr igerant Recovery, Recycling and Recharging procedure) 2. Loosen the hexagonal nut and take out pressure switch. Installation 1. Tighten the hexagonal nut and fit pressure switch. 2. Recharge the system using RRU. (Refer Refrigerant Recovery, Recycling and Recharging procedure) KINEMATICS Removal 1. Remove HVAC unit. (Refer HVAC unit removal procedure) 2. Remove bowden cable fixing clips (As shown above). 3. Disengage the HVAC control cables and remove the Kinematics from HVAC unit. Installation 1. Install kinematics (press fit type). 2. Engage HVAC control cables and fix clips. 3. Install HVAC unit. (Refer HVAC unit installation procedure)