TIGOR EV_ZIPTRON_SERVICE MANUAL

HV ELECTRICAL SYSTEM 34 6. HV CONNECTOR CONNECTION & LOCKING PROCESS A. PDU TO E - COMPRESSOR 1. PDU CONNECTOR  SETP-1 Make sure secondary lock is in original position as shown setp 1  SETP-2 connect female PDU connector to male PDU side connector and push untill you hear click sound  SETP-3 Slide secondary lock upward ( refer setp – 3 for final position of secondary lock ). 2. E- COMPRESSOR CONNECTOR  SETP-1 Slide secondary lock Downward.