NEXON BSVI MCE - SERVICE MANUAL

TRANSAXLE TA6300 29 10. Remove DETENT ASSY (SHIFTER SHAFT) as shown & take out housing, Rear half. 11. Remove Hex FL bolt M8X25 for Reverse Idler. 12. Remove snap ring on deep groove ball bearing as shown 13. Remove three Hex FL Bolt M8X45.from inside from front housing half. 14. Remove Hex FL Bolt M8X45 (13 nos). 15. Unscrew hex Flange screw M8x22 & take out reverse Lever bracket Assy. 16. Take out input shaft assembly, Lay shaft assembly, reverse shaft assembly & all shifter shaft assembly. 17. Remove wiring harness Bracket. 18. Remove cable-anchoring Bracket.