NEXON BSVI MCE - SERVICE MANUAL

1.5L REVOTORQ BS VI ENGINE 104 7. Disconnect electrical connection to the temperature sensors. 8. Remove the mounting fasteners and take down the LNT+DPF assembly. FITMENT For fitment follow removal procedure in reverse. NOTE  Flushing operation for cleaning the catalytic converter should be done by directing dry compressed air draft in the direction of catalytic converter inlet, after removing it from the vehicle.  Ensure flex bellow should not be pre stress or bend as shown in below figure & also ensure proper orientation of rubber hangers