NEXON BSVI MCE - SERVICE MANUAL
1.5L REVOTORQ ENGINE 54 7. Step to be follow during de-aeration process with coolant quantities. Sr. No. Stage Action Coolant Qty. (ml) 1 Initial filling Fill the coolant through pressure cap opening 3700 2 Cold fill – Engine off Coolant filled until max level of no loss tank 700 3 Pressure cap closed. Engine started & maintained at 3000±100 rpm with AC OFF. 4 2 Heat –Cool cycles done (i.e. Radiator fan turns ‘ON’ & ‘OFF’ for two times). 5 Engine OFF. Leave engine to cool down (preferably to ambient temperatures). 6 2nd filling Fill the coolant till neck of pressure cap 200 Fill the coolant till max level 400 Total Coolant filled 5000