NANO

208 ENGINE 273 MPFI • Take out the new pre-calibrated Level Sensor Assembly from the cover. • Assemble the new pre- calibrated Level Sensor Assembly with the assistance of two locating pins provided on Level SensorAssembly and themating guiding holes provided on the Flange. • Press the new pre- calibrated Level Sensor Assembly unit you hear the click sound of clips being locked. Visually confirm clipping on flange • Reconnect the electrical connector of the Level Sensor Assembly. Ensure that blue wire is connected to S+ and black wire is connected to S- terminal. Assembly procedure : NOTE: • Spare level sensor assembly does not require cali- bration since it is precalibrated with master flange. • Do not handle the spare level sensor assembly by lever float assembly since it might lead to distur- bance in calibration values due to any changes in the bend angles of the lever. • Hold the dissembled Level sensor Assembly Fuel Supply Unit upside down. Clip B Clip A