NANO
206 ENGINE 273 MPFI • Disconnect electrical connector. • Unscrew the six hexagonal mounting bolts. • Take out the entire assembly along with cover plate and gasket. • Take out the gasket and cover plate from the assembly. WARNING Unless replacement is necessary, fuel module should not be removed from the tank since the rubber parts i.e. gasket, seals etc. may get exposed to air, light and may become hard. Never apply an excessive force to the fuel pump nipple or lead wire. This may result in bend or poor contact. 2.1.Fuel Level Sensor Assembly/Float Unit Precautions: Following precautions should be taken during assembly & dismantling of fuel level sensor assembly/ float unit. • The level sensor assembly should not be held by lever assembly or cable assembly. • It has to be ensured that the fuel level sensor assembly is assembled in a clean area, immediately after opening the packing. • During installation, the float lever arm should not be touch the sides of the tank opening. • Precaution to be taken to avoid dropping the unit to avoid damage whichmight affect the functioning. • The lever sensor should not be directly connected to the battery (12V). • Under delivery packing condition, the level sendor assembly is already calibrated. • Long term storage (upto 2 years) can only be permitted if the units have been separately packed in air tight containers. (This is essential for spare parts and overseas transportation).