NANO

ELECTRICAL 41 Sr No DTC Code DTC Descriptio n Minimum Time for Fault Setting / Tester Visibility, Assuming Fault was created while Ignition was OFF Impact on customer Probable cause Investigation/Rectificati on/Repair action 21 B1914 12 Turn Left Indicator Input - circuit short to battery Post execution of Service Self-Test Routine (or) EOL Self-Test Routine <= 20sec delay time. Turn Left tell tale will always be ON till this DTC is active. Turn left input short Turn left input shorted to battery positive. 22 B1915 11 Turn Right Indicator Input - circuit short to ground Post execution of Service Self-Test Routine (or) EOL Self-Test Routine <= 20sec delay time. Turn Right tell tale will always be OFF till this DTC is active. Turn right input short Turn right input shorted to battery negative or ground. 23 B1915 12 Turn Right Indicator Input - circuit short to battery Post execution of Service Self-Test Routine (or) EOL Self-Test Routine <= 20sec delay time. Turn Right tell tale will always be ON till this DTC is active. Turn right input short Turn right input shorted to battery positive. 24 B1916 12 Hazard Signal Indicator Input - circuit short to battery If Turn indicators R & L are active more than >2sec Turn Left & Right tell tale will always be ON till this DTC is active. Hazard input short Hazard input shorted to battery positive. 25 B1934 09 Set Switch Button Stucked SET knob continuous press > 20 sec Customer will not able to do the clock settings, ETM mode, Illumination setting and one time odo reset till this DTC is active. Set button damage Check Button mechanism

RkJQdWJsaXNoZXIy MTIwNTUz