NANO

FUEL SYSTEM 6 CYLINDER VALVE MAINTENANCE PROCEDURE: There is no preventive maintenance require for Cylinder valve. However in case of damage of solenoid coil / valve due to certain adverse conditions, it may be necessary to replace the solenoid coil / valve. Solenoid coil / valve replacement procedure:  Disconnect the electrical connections.  Unscrew the fixing nut on top of the coil.  Remove the coil / valve as shown and change it with the new one. CAUTION  Always use only original valve / coil with proper specification.  Apply lubricant Loxeal 85-21 on 2-3 threads of fixing nut and remove excess lubricant.  Re-screw the fixing nut and tighten to a torque of 0.7 Kg-m.  Re-connect electrical connection. 8