TA6300 AMT KIT 9 Lubricate with new ‘CS Speed’ oil the “Mechatronic Gear Actuator” seats for connectors with O-rings. Assemble the spare part gasket on the spare part “Mechatronic Gear Actuator” with the correct orientation, inserting the centering pins into the fixing holes of the “Mechatronic Gear Actuator” body. Position the “Mechatronic Gear Actuator” with gasket over the “Power Unit Base Plate”, using for reference the threaded rods and moving it parallel towards the mating surface. When the “Mechatronic Gear Actuator” body seats come in contact with O-rings push it slowly with appropriate load to complete the assembly. Unscrew the rods and screw without tighten the three spare parts screws for fixing the “Mechatronic Gear Actuator” on “Power Unit Base Plate”. Tighten screw at the right torque 10 ± 1 Nm, following the order shown in the image below. Connect the connector of the wiring harness on the ‘Transmission Control Unit’. Fill the ‘Oil Tank’ with new ‘CS Speed’ oil, up to the Max. Level “@ 0 bar” (no pressure in the hydraulic circuit) and restore it after the purge procedure. Screw the ‘Oil Tank Cap’ at the right torque 2 - 0.5 ± 1 Nm.