FATC 30 1.14. OVERHAULING FRONT FATC UNIT WARNING Coolant will be present in the heater coil, so carefully tilt the HVAC unit and collect the coolant in an ap- propriate container to avoid it spilling onto the technician . 1. Remove the electrical connection from blower. 2. Remove the electrical connection of resistor. 3. Remove the electrical connection from Thermo sensor. 4. Take out Thermo sensor. 5. Remove the electrical connection of the recircu- lating actuator. 6. Remove the electrical connection of the actuator.