HVAC 29 STEP INSPECTION ACTION 16 Verify whether malfunctions is in compressor oil amount or a/c com- pressor after compressor oil is replenished each 10 ml, does high- pressure value increase? Yes Troubleshooting completed. (Explain to customer that cause was insufficient compressor oil.) No Replace A/C compressor. (Cause is defective AC compressor) 17 Verify whether malfunction is in expansion valve or elsewhere is only refrigerant low-pressure value high? Yes Go to step 20. No Go to next step 18 Verify that air mix is installed se- curely and properly are heater unit’s air mix links, air mix cranks and air mix rods securely and properly installed? Yes Go to next step No Repair or install links, cranks and rods securely in proper position. 19 Verify that expansion valve heat- sensing tube within cooling unit is positioned securely and correctly is expansion valve heat-sensing tube within cooling unit securely in- stalled in proper position? Yes Replace expansion valve, then go to next step. (Since valve opens too much, replacement is necessary.) No Install heat-sensing tube securely in proper posi- tion, then go to next step. 20 Verify that malfunction symptom occurs after repair does cool air blow out? (Are results of refrigerant system performance test okay?) Yes Troubleshooting completed. Explain repairs to customer. No Recheck malfunction symptoms, then repeat from step 1 if malfunction recurs.