NEXON
ELECTRICAL 202 5.3 AUTO RELOCK 5.3.1 Description For added security, when the vehicle is Unlocked and if any of the doors is not opened for a predefined time, then the vehicle shall get locked after this predefined time elapsed. Auto Relock feature in a vehicle shall be configurable during service. 5.3.2 Conditional Requirements Activation – • RKE unlock is provided & • If no door is opened for the time period 30 seconds Exit Condition Within 30 sec if, • Ignition Key must be at ON position • Any door is opened • Key is inserted 5.3.3 Operating Voltage Range DESCRIPTION REQUIREMENT VOLTAGE Auto Relock. Normal operating voltage 12V Min & Max operating voltage range 9V-16V 5.3.4 Inputs & Outputs