ELECTRICAL 136 FOR 20 PIN CONNECTOR (APPLICABLE FOR LOW END) SR. NO DESCRIPTION TYPE OF INPUT INPUT /OUTPUT ACTIVE LEVEL/ STATE DIAGO- NASTIC IC-Low end IC-High End 1 NC 2 NC 3 NC 4 NC 5 NC 6 NC 7 NC 8 Driver Door Open IN Digital Input Low NA Y NA 9 Turn Right IN Digital Input High NA Y NA 10 Key IN Digital Input High NA Y NA 11 NC 12 NC 13 NC 14 NC 15 NC 16 NC 17 Park Bulb IN Digital Input High NA Y NA 18 All Other Door Open IN Digital Input Low NA Y NA 19 NC 20 Turn Left IN Digital Input High NA Y NA NA-Not applicable, PP- Package protected, Y- applicable. 1.25.5 FUEL GAUGE DETAILS Fuel level indication FUEL VS RESISTANCE TABLE FOR INSTRUMENT CLUSTER HIGH END SEGMENT TANK LEVEL(Lit) RESISTANCE (OHMS) BAR ON RESISTANCE (OHMS) BAR OFF RESISTANCE (OHMS) LOW FUEL WARING TT TOLERANCE(±2 OHMS) SHORT CIRCUIT 5 BLINK @ 2Hz 44.0 6 6 42.0 10 12 22 OFF 5 35.7 24 26 38 OFF 4 29.3 40 42 54 OFF 3 23.0 56 58 74 OFF 2 15.5 76 78 95 OFF 1 8.0 97 99 109 ON ( 2 nd bar OFF) 1 BAR BLINK 4.0 111 IGN ON ON 1.5 120 134 OPEN CIRCUIT 135 BLINK @ 2Hz