TIAGO TIGOR BSVI - SERVICE MANUAL - DTC 24-12-2021

X0 MCE (Tiago / Tigor) Instrument Cluster DTC Troubleshooting Data Version: 1.4 Date: 14-Dec-19 Author: Jeeva Raj / Sharad Shivane Page: 10 of 135 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Trouble Shooting:- Turn ON Ignition. Connect the TML Diagnostic Tool. Check the status of DTC’ s (Memorized/Current) Record the DTC & Clear DTC’ s Turn Ignition OFF & ON Verify If DTC B190B -11 is present Is DTC B190B-11 is Present? Check for continuity between Pin No.J1-10(GND) & J1-29 of ECU Connector. Is Continuity Present? OAT input is Short Circuit to Ground. Rectify Fault at wiring Harness & wait for 20sec to recover the fault. Clear the DTC. Verify the function of OAT Sensor with multimeter & OAT value on LCD display. Clear the DTC from the ECU memory. Turn Ignition OFF & ON. Press the mode switch button one time to show the OAT display value & Check whether display is showing the OAT value in Deg ’ C. Stop Stop YES NO YES NO Stop

RkJQdWJsaXNoZXIy MTIwNTUz