HVAC 60 10.4. OVERHAULING FRONT HVAC UNIT DISMANTLING !! WARNING Coolant will be present in the heater coil, so carefully tilt the HVAC unit and collect the coolant in an ap- propriate container to avoid it spilling onto the technician. 1. Remove the electrical connection from blower. 2. Loosen and remove three mounting bolts 3. Remove the c lips. 4. Separate the blower from the assembly. 5. Remove the electrical connection of resistor.