TIAGO

HVAC 55 10.3.8. HVAC UNIT REMOVAL 1. Discharge the refrigerant using standard recover- ing equipment. 2. Remove dash board assembly. (For procedure refer dashboard removal.) 3. Disconnect all electrical connections. 4. Remove cross car beam (For procedure refer body group). 5. Loosen and remove bolts and disconnect the inlet and outlet lines i.e. high pressure line and low pressure line and plug the ports. 6. Disconnect the Heater inlet (1) and heater coil outlet (2) pipes. !! WARNING  The heater pipes contain hot coolant which may spill out when disconnected, even if the coolant is drained, so be careful while disconnecting them.  Keep a suitable container below it to collect the coolant that will flow out. 7. Loosen and remove mounting bolts (5 Nos) as shown in figure below and take out the HVAC unit. FITMENT For fitment follow the reverse procedure of removal. 10.3.9. CONDENSER SEALING DUCT REMOVAL 1. Remove the bumper (Refer Body section). 2. Open the bonnet. 3. Remove horns from both ends. 4. Loosen and remove mounting screws. FITMENT For fitment follow the reverse procedure of removal .