Automated Manual Transmission 12 This image shows the variation of the output voltage (VS) according to the position of the magnet. As the sensor operates with an alternating voltage, regardless of the movement of the magnet to the right or the left of the sensor, the effective value of the output voltage will be the same. To determine whether the movement of the magnet is to the left or to the right, the electronic sensor control circuit analyses the phase difference between the VP voltage applied to the primary coil and the total voltage VS. If the phase of the voltage VS is the same of the phase of the voltage VP, the magnet moves to the right and vice versa. Technical data: Primary resistance 35 Ω +/- 15% Secondary resistance 21 Ω +/- 15% NOTE: The electronic circuit to read the signal gen- erated by the PLCD is installed inside the NCR.