Background Image
Table of Contents Table of Contents
Previous Page  389 / 516 Next Page
Information
Show Menu
Previous Page 389 / 516 Next Page
Page Background

FATC

2

PRESSURE SENSOR

Type

Linear Pressure Sensor (LPS)

coil voltage (Applicable Voltage)

8 V - 16V

Pressure Sensor setting

Low Pressure

OFF

0.196 +/- 0.02 MPa

ON

0.225 (+0.025, - 0.029) Mpa

Middle Pressure

OFF

1.52 +/- 0.15 MPa

ON

2.01 +/- 0.1 MPa

High Pressure

OFF

2.8 +/- 0.2 Mpa

ON

(2.4) Mpa

Current drawn (Min operating current)

10 mA

Fresh air / recirculation mode

Actuator operated

Temperature control

AUTO as well as Manual over ride

Mode control

AUTO as well as Manual over ride

Blower resistor

LPM Type

Blower motor

BOSCH