FATC

26

a.

.

AIR FROM VENTS NOT COLD ENOUGH

TROUBLESHOOTING HINTS

Drive belt malfunction: Step 1

Malfunction in blower unit or condenser: Step 4, 5

Malfunction in receiver / drier, expansion valve ( valve close too much) or expansion valve heat-sensing tube

installed incorrectly: Step 8, 9

Malfunction in refrigerant lines: Step 10- 13

A/C compressor system malfunction, insufficient compressor oil: Step 16

Too much compressor oil, expansion valve heat-sensing tube installed incorrectly, or malfunction in expan-

sion valve or heater unit’s air mix link system: Step 18- 19

TROUBLE SHOOTING

Step

Inspection

Action

1

Inspect drive belt

See whether the belt is present or fitted

with correct tension.

Yes

Go to next step

No Adjust or replace drive belt.

2

Inspect refrigerant system performance

Perform refrigerant system performance

test (

Refer AC system performance test)

Is operating normal?

Yes

Operation is normal. (Recheck malfunction

symptoms.)

NO Go to next step

3

Verify whether malfunction is in blower

unit intake and condenser or another Are

refrigerant’s high-pressure and low pres-

sure values both high?

Yes Go to next step.

No Go to step 6.

4

Inspect blower unit intake Is blower unit

intake clogged

Yes

Remove obstruction.

(If air does not reach evaporator within cool-

ing unit, heat exchange does not occur,

refrigerant pressure becomes high, and there-

fore, removal of obstruction is necessary.)

No Go to next step

5

Inspect condenser

is it okay?

Yes

Adjust refrigerant to specified amount.

(Excessive amount of refrigerant.)

No

Replace condenser, or repair and clean con-

denser fins.

6

Verify whether malfunction is in expan-

sion valve,

receiver/drier and refrigerant lines or

elsewhere

Are refrigerant’s high-pressure and low-

pressure values low?

Yes Go to next step

No Go to step 14

7

Verify whether malfunction is in expan-

sion valve and receiver /drier or

elsewhere immediately after A/C com-

pressor operates, Does refrigerant’s high-

pressure value momentarily rise to cor-

rect value, then fall and stay below it?

(Is

there negative pressure on low-pressure

side?)

Yes Go to next step

No Go to step 10.