STEERING

32

STEERING

ANGLE

CALIBRATION

PROCEDURE

It is necessary to calibrate and initialize the EPAS

ECU in order to correctly startup the steering

system.

Calibration: When calibr

ating, the steering gear’s/

front axle’s straight

-ahead position is compared

with the straight-ahead position of the steering

column’s internal steering angle. For Calibrating

the EPAS ECU,

use either Mando Test Man or

diagnostic tester.

Initialization and teach-in software end stops: This

is done by steering past the index position on the

internal torque sensor (the steering column) in the

straight-ahead position, when steering left and

steering right. At the same time, the software end

stops are taught i

n. After initializing, “Active reset”

& “software end stop” functions will be active

NOTE:

While doing the steering angle calibration and

initialization process, Please follow the

instruction which are displaying on Diagnostics

tool window.

If required, before doing steering angle

calibration and initialization process, operator

needs to do first rack centralization followed by

wheel alignment on vehicle as per

specification.

If steering angle calibration process is not

completed, than EPAS warning lamp will glow

in IPC.