ELECTRICAL

237

4.5 ACTIVE WAKE-UP CAPABILITY

4.5.1 Description

BCM shall get wakeup by the below mentioned wakeup inputs signals (Inputs and Outputs section). BCM

shall wakeup other ECU's with a hardwired wakeup signals based on the wake-up functional requirements.

BCM shall not be required to wake-up other ECUs or woken up by other ECUs on CAN. Only hardwired

wake up and LIN BUS wakeup shall be required.

BCM shall get woken up with any of the below mentioned signal inputs:

Drive Door State

Co-Driver Door State

Other Door State signal

Rear RH door signal

Rear LH door signal

Tail gate signal

Bonnet signal

Driver Door Lock Signal

Driver Door Unlock Signal

Infotainment removal detection

Brake switch signal

Ignition KeyIN signal

Position lamp switch signal

Low Beam Switch Signal

Main Beam Switch Signal

Ignition key IGN signal

Hazard switch signal

Head lamp ON switch signal

Ignition ACC signal

Remote key signals (RF)

LIN bus signals (if any)

BCM Power Reset

4.5.2 Conditional Requirements

BCM shall make hardware wakeup signal output ON and send the corresponding CAN and/or LIN signals

when any of the wake-up input is received.

If BCM detects the new wake-up input then it should activate the wake-up signal output again.

Wake-up output signal pulse ON time (T ON) shall be 100 mSec.

4.5.3 Operating Voltage Range

DESCRIPTION

REQUIREMENT

VOLTAGE

Active

Wake-up

Capability

Normal operating voltage:

12V.

Normal Operating Voltage Range For Hazard:

6.5V - 16V.

Normal Operating Voltage Range For CAN & LIN

Communication:

7V - 16V.

Normal Operating Voltage Range For Other:

9V - 16V