HVAC

24

Detent Position

Knob Angle in

Degrees (CW

starting from the

initial position)

Voltage

Min (V)

Nominal (V)

Max (V)

2

18

0.88

0.93

0.98

3

27

0.99

1.04

1.09

4

36

1.11

1.16

1.21

5

45

1.22

1.27

1.32

6

54

1.34

1.39

1.44

7

63

1.45

1.50

1.55

8

72

1.56

1.61

1.66

9

81

1.68

1.73

1.78

10

90

1.79

1.84

1.89

11

99

1.91

1.96

2.01

12

108

2.02

2.07

2.12

13

117

2.14

2.19

2.24

14

126

2.25

2.30

2.35

15

135

2.37

2.42

2.47

16

144

2.48

2.53

2.58

17

153

2.59

2.64

2.69

18

162

2.71

2.76

2.81

19

171

2.82

2.87

2.92

20

180

2.94

2.99

3.04

21

189

3.05

3.10

3.15

22

198

3.17

3.22

3.27

23

207

3.28

3.33

3.38

24

216

3.39

3.44

3.49

25

225

3.51

3.56

3.61

26

234

3.62

3.67

3.72

27

243

3.74

3.79

3.84

28

252

3.85

3.90

3.95

29

261

3.97

4.02

4.07

30

270

4.08

4.13

4.18