HVAC

28

Step

Inspection

Action

14

Verify whether malfunction is in expan-

sion valve, air mix and compressor oil or

elsewhere Does refrigerant’s high-

pressure value hardly increases?

Yes

Go to next step.

(Pressure hardly increases.)

No Go to step 17.

15

Verify whether a malfunction is in com-

pressor oil amount and a/c compressor or

elsewhere when engine is racing, Does

high-pressure value increase?

Yes Return to step 3.

No Go to next step

16

Verify whether malfunctions is in com-

pressor oil amount or a/c compressor

after compressor oil is replenished each

10 ml, Does high-pressure value in-

crease?

Yes

Troubleshooting completed.

(Explain to cus-

tomer that cause was insufficient compressor

oil.)

No

Replace A/C compressor.

(Cause is defective

AC compressor)

17

Verify whether malfunction is in expan-

sion valve or elsewhere Is only refrigerant

low-pressure value high?

Yes Go to step 20.

No Go to next step

18

Verify that air mix is installed securely

and properly Are heater unit’s air mix

links, air mix cranks and air mix rods se-

curely and properly installed?

Yes Go to next step

No

Repair or install links, cranks and rods se-

curely in proper position.

19

Verify that expansion valve heat-sensing

tube within cooling unit is positioned se-

curely and correctly Is expansion valve

heat-sensing tube within cooling unit se-

curely installed in proper position?

Yes

Replace expansion valve, then go to next

step.

(Since valve opens too much, replace-

ment is necessary.)

No

Install heat-sensing tube securely in proper

position, then go to next step.

20

Verify that malfunction symptom occurs

after repair Does cool air blow out?

(Are

results of refrigerant system performance

test okay?)

Yes

Troubleshooting completed.

Explain repairs to customer.

No

Recheck malfunction symptoms, then repeat

from step 1 if malfunction recurs.