BRAKES

27

BRAKE BLEEDING THROUGH SOFTWARE:

A normal bleeding procedure can be employed

whenever:

Changing brake fluid as per the service

intervals / schedule.

Replacing new brake system part like ABS

hydraulic unit, master cylinder, wheel

cylinders, correction valves and repair of

hydraulic lines.

Spongy / Soft brake pedal or pedal travel high

complaint.

In below mentioned specific cases, bleeding

process known as “ABS Secondary Circuit

Bleeding” is to be employed. In this method

solenoid valve and the pump motor are actuated

by Software based TML - diagnostic system.

If customer service intervals are exceeded 5

yrs. or more.

Brake pedal feels soft following ABS

application.

NOTE: Before conducting “ABS Secondary

Circuit bleeding” a normal bleeding should be

performed.

NOTE: Please refer to TML diagnostic tool for

ABS system bleeding