GENERAL

3

1.2 PRECAUTION FOR ELECTRICAL

CIRCUIT SERVICE:

Disconnect the negative cable of the battery

while servicing the electrical parts that do not

require battery power and insulate the

negative terminal properly.

While removing the battery first disconnect

the negative cable and then the positive

cable. While reinstalling the battery, first

connect the positive cable and then negative

cable.

Be sure to turn the ignition switch off before

disconnecting and connecting coupler to

avoid electronic parts damage

Do not touch the electrical terminals of parts

which use microcomputers (e.g. electronic

control units like ECM etc.) to avoid damage

to these parts from static electricity from your

body

Always use the correct voltmeter, ohmmeter

for taking measurement to avoid damage to

the electronic control unit and sensors.

Make sure to insert the probe from wire

harness side of the connector for taking

measurement.

Make sure the connector halves are mating

properly and terminals seating precisely in the

connector body.

Dirt / corroded terminals result in improper

contact. The terminals should be cleaned

carefully.

Improper contact pressure between mating

terminals disturbs the connectivity between

them.

Replace the damaged connector body to

avoid exposure of the terminals in case of

inadequate contact pressure.