AIR CONDITIONING

60

11.18.10 Diagnosis Trouble Codes

B1F2B-12

Air Conditioning Compressor Request – circuit short to battery

B1F2B-11

Air Conditioning Compressor Request – circuit short to Ground

B1F3E-71

Temperature Door Control Motor - Actuator stuck

B1F3E-54

Temperature Door Control Motor Calibration Fault

B1F2D-12

Temperature Door Control Motor Drive Line - Circuit Short to Battery

B1F2D-11

Air Temperature Motor Drive Line- Circuit Short to Ground

B1F2D-13

Air Temperature Motor Drive Line- Circuit Open

B1F47-13

Air Temperature Feedback Power Supply- Circuit Open

B1F20-11

Air Temperature Feedback Power Supply- Circuit Short to Ground

B1F20-12

Air Temperature Feedback Power Supply- Circuit Short to Battery

B1F1F-15

Air Temperature Feedback Signal - Circuit Short to Battery or Open

B1F1F-11

Air Temperature Feedback Signal - Circuit Short To Ground

B1F2F-13

Blower Motor Drive Signal - Circuit Open

B1F28-12

Blower Motor Diagnostic Feedback OR Blower Motor DTC - Circuit Short to Battery

B1F28-14

Blower Motor Diagnostic Feedback - Circuit Short to Ground or Open

B1F2F-12

Blower Motor Drive Signal - Circuit Short to battery

B1F2F-11

Blower Motor Drive Signal - Circuit Short to Ground

B1F2A-12

Cabin Temperature Sensor - Circuit Short to Battery

B1F2A-14

Cabin Temperature Sensor - Circuit Short to Ground or Open

B1F23-15

Evaporator Temperature Sensor Signal - Circuit Short to Battery or Open

B1F23-11

Evaporator Temperature Sensor Signal - Circuit Short to Ground

B1F46-13

Fresh Air/RECIRC Feedback Power Supply - Circuit Open

B1F2C-13

Fresh Air/RECIRC Motor Drive Line- Circuit Open

B1F2C-12

Fresh Air/RECIRC Motor Drive Line- Circuit Short to Battery

B1F4B-56

BCM configuration Error- Invalid/Incompatible Configuration

B1F2C-11

Fresh Air/RECIRC Motor Drive Line- Circuit Short to Ground

B1F1E-12

Fresh Air/RECIRC Feedback Power Supply - Circuit to Battery

B1F1E-11

Fresh Air/RECIRC Feedback Power Supply - Circuit Short to Ground

B1F1D-15

Fresh Air/RECIRC Feedback Signal - Circuit Short to Battery or open

B1F1D-11

Fresh Air/RECIRC Feedback Signal - Circuit Short to Ground

B1F3F-71

Fresh Air/RECIRC Drive Motor – Actuator stuck

B1F3F-54

Fresh Air/RECIRC Drive Motor – Missing calibration

U161B-64

HuCCmConfigAck Data Mismatch or Not Received From HU - Signal Plausibility Failure

B1F2E-12

Air Distribution Motor Drive Line– Circuit short to Battery

B1F2E-11

Air Distribution Motor Drive Line– Circuit short to Ground

B1F3D-54

Air Distribution Motor Drive Line– Missing calibration

B1F3D-71

Air Distribution Motor Drive Line– Actuator stuck

B1F22-12

Air Distribution Feedback Power Supply – Circuit short to Battery

B1F22-11

Air Distribution Feedback Power Supply – Circuit short to Ground