Background Image
Table of Contents Table of Contents
Previous Page  451 / 1131 Next Page
Information
Show Menu
Previous Page 451 / 1131 Next Page
Page Background

1.5L REVOTORQ ENGINE

196

STAND ALONE DIAGNOSIS / SENSOR

CHECKING PROCEDURE

OPERATING SPECIFICATION

Equipment

:

Use Multimeter

Power Supply :

6-16V

Checking

:

With Ignition 'ON',

Condition

:

Voltage between GND and

Vout

Signal Voltage :

4.7V (When the Flag is not in

front of the sensor)

:

0.6V (When the Flag is in

front of the sensor)

Operating Temperature:

-30

0

to 120

0

C

Air Gap:

0.5-1.5 mm

Target Speed:

0-4000 rpm

CONNECTOR DETAILS

PINOUT DETAILS

Pin No

Description

1

Ground

2

Vout

3

Vs

iv. AIR MASS FLOW SENSOR

This sensor is mounted between air filter and

turbocharger. It gives Information about the

amount of air quantity & temperature entering the

engine.

This input is used by the ECU for corrections of

fuel quantity based on amount of air availability for

optimization of exhaust gas circulation & the

turbocharger control. While assembling, the AMF

sensor the point of the arrow should be towards

the Turbo charger.

SENSOR LOCATION

Checking Condition

With Ignition 'ON',

Check Output Voltage between Pin 3

(MAF) and Pin 5 (GND).

Check Output Current between Pin 1 (Ub)

and Pin 5 (GND).

Signal/Output Current

The current consumption has to be between 35

and 55mA.