HVAC

2

RECEIVER DRIER BOTTLE

Type

Integral RD

Type of desiccant

Synthetic Zeolite, XH-9 or A-3RG, 14g adb

Material

Aluminium

THERMISTER /THERMO AMPLIFIER

NTC type

ON setting

4

0

C ± 0.5

0

C

OFF setting

2

0

C ± 0.5

0

C

PRESSURE SWITCH

Trinary

Coil voltage ( Applicable Voltage )

8 V - 16V

Pressure switch setting & type

Low Pressure

OFF

0.196 +/- 0.02 MPa

ON

0.225 (+0.025, - 0.029) Mpa

Middle Pres-

sure

OFF

1.52 +/- 0.15 MPa

ON

2.01 +/- 0.1 MPa

High Pressure

OFF

3.14 +/- 0.2 Mpa

ON

(2.55) Mpa

Current drawn

Min operating current 10 mA

FRESH AIR / RECIRCULATION MODE

Actuator operated

TEMPERATURE CONTROL

Actuator operated

MODE CONTROL

Actuator operated