TIAGO AMT Gasoline

DTC Troubleshooting Guide

Version: 2.0

Date: 06-06-2016

Author: Sathi/Anupama

Page: 424 of 424

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

140 P1C13-

02

Invalid Data Received From

ECM-Message Rolling Counter

Error

-EMS (108 frame) rolling counter does not

change in two consecutive frames.

-Electromagnetic

interference

- High frequency noise.

141 P1C14-

01

Invalid Data Received From IPC-

Cyclic Redundancy Check Error

-IPC(197 frame)Checksum different from

that one received

-Electromagnetic

interference

- High frequency noise.

142 P1C15-

02

Invalid Data Received From IPC-

Message Rolling Counter Error

-IPC (197 frame) rolling counter does not

change in two consecutive frames.

-Electromagnetic

interference

- High frequency noise.

143 P1986-

07

Variant code procedure not

completed

Variant code procedure not executed

Variant code procedure

not executed

144 U0001/0

2

Engine LimpHome signal

Fault at accelerator pedal assembly

Fault at accelerator

pedal assembly