ELECTRICAL

104

FUEL VS RESISTANCE TABLE

FOR INSTRUMENT CLUSTER LOW END

SEGMENT

TANK

LEVEL(Lit)

RESISTANCE

(OHMS)

BAR ON

RESISTANCE(OHMS)

BAR OFF

RESISTANCE(OHMS)

LOW FUEL

WARING TT

TOLERANCE(±2 OHMS)

SHORT

CIRCUIT

5

BLINK @ 2Hz

10

42

8

10

16

LFW OFF

9

38.2

18

20

26

LFW OFF

8

34.4

28

30

35

LFW OFF

7

30.6

37

39

44

LFW OFF

6

26.8

46

48

54

LFW OFF

5

23

56

58

64

LFW OFF

4

19.3

66

68

74

LFW OFF

3

15.5

76

78

84

LFW OFF

2

11.8

86

88

95

LFW OFF

1

8

97

99

109

LFW ON with

2nd Segment

OFF

1 BAR

BLINK

4

111

IGN ON

LFW ON

OPEN

CIRCUIT

135

BLINK @ 2Hz

12.24.6 TEMPERATURE BAR GRAPH DETAILS

:

Temperature indication:

TEMPERATURE CALIBRATION TABLE

SEGMENT BAR ON TEMP. (ºC) BAR OFF TEMP. (ºC)

6seg

120

115

5seg

115

110

4seg

110

105

3seg

90

85

2seg

85

80

1seg (C)

-40

NA

Input type:

Can

Output:

LED bar graph in Instrument Cluster high end.

Absent in Instrument Cluster low end.

ECT TT (Duel Colour)